    Our new TCAT-2 family of general purpose PID Autotuning Controllers provides accurate temperature control in a variety of laboratory applications. Combined with a heat lamp or heating pad, the TCAT-2 may be used to maintain the body temperature of anesthetized animals during surgery or stereotaxic procedures. Small animal cages are easily warmed with a heat lamp. The TCAT-2 may also be used in cooling applications, such as to control independent perfusate cooling systems. Realizing that laboratory applications are diverse, Physitemp can provide several versions of the TCAT Controller. The model specified depends on whether a laboratory has a general or specific need for the controller:

    TCAT-2AC:
    This version controls only AC powered heating or cooling devices such as a heat lamp. It is the least costly.

    TCAT-LV:
    This model provides a low-voltage DC output for electrically sensitive applications where AC frequencies might interfere with other monitoring devices. It comes standard with a built in DC power supply designed to operate with our HP-1M Heating Plate for small rodents. The TCAT-2LV utilizes a dual set point control circuit to prevent a heating element from overshooting the control point due to thermal lag in the control system. This is an important feature in preventing burns due to incorrect control settings or faulty feedback sensor. On a custom basis, we can provide a variety of DC power supplies Depending on the load power requirements.

    TCAT-2DF:
    This is a combination version which includes both an AC outlet for controlling primarily resistance loads such as heat lamps, AC powered warming blankets and a low-voltage, low-noise" DC output for heating pads. This version allows you to control a variety of different loads.

    All TCAT-2 versions may be used with any of our extensive line of accurate Type T thermocouple probes, which act as the temperature feedback sensor. Most commonly used are the RET series of animal rectal probes, but the IT series of implantable flexible probes and MT series of needle probes may also be used depending on the specific application. All instruments are designed to operate on a 110V or 230V AC supply.

    The unit comes in a durable baked enamel painted aluminum housing. Adjustable front feet allow the user to raise the front of controller to provide a more convenient viewing angle.

    A heat/cool switch is provided when using the controller with cooling devices such as small refrigeration compressors or thermoelectric stages. In the cooling mode it inverts the control function and shuts off the load when feedback sensor temperature falls below the set point. A small lamp on the front of the control unit indicates when power is being applied to the load.

    The TCAT-2 is simple to set-up; connect the feedback sensor to the animal and to the back of the controller, connect the heating pad, blanket, lamp or cooling device to the appropriate outlet on the rear of the controller. Adjust the set temperature as required (lower green display) according to the instruction label on top of the instrument. The set temperature is stored in memory after the unit is switched off.

    Features

    Controls heating blankets heat lamps or heating pad.

    Can be used for both heating and cooling applications.

    110 to 230V AC line operation

    Control Range of -100 to +400°C

    Resolution 0.1°C

  •  

     

    Specifications

    Resolution

     

    ±0.1°C

    Accuracy

     

    ± 0.5°C

    Range

     

    Ambient +2° to 60°C

    Readout

     

    Dual display of Set (red) and Run(red) temperatures

    Max AC Power Output with resistive load

     

    700 watts (Does not apply to TCAT-2LV)

    DC Output Rating:

     

    TCAT-2DF and TCAT-2LV: 12V DC, 2 Amps Max. Custom output voltages available upon request(Does not apply to TCAT-2AC)

    AC ground leakage current

     

    less than 1 millamp at 110 V AC

    Dual Setpoint Protection Feature

     

    TCAT-2DF and TCAT-2LV onlyadditional heating pad feedback sensor prevents temperature exceeding 45°C.

    Dimensions

     

    7 1/4" W x 4 3/8" H x 10" D

    Weight

     

    Less than 5 lbs.

    Power Supply

     

    110V or 220 V AC

  •  Please call for details 

  •  Please call for details 

ICP備案號: 滬ICP備15057650號-1 滬公網安備31011202005471
雷萌生物科技(上海)有限公司 保留所有版權.

首頁   |   產品中心   |   產品應用   |   技術支持   |   新聞中心   |   關于我們   |   ibidi官網
主站蜘蛛池模板: 国产美女精品自在线拍免费 | 国产超级va在线观看视频| aaa午夜级特黄日本大片| 日本xxx在线观看免费播放 | 久久中文字幕人妻熟女| 国产精品高清一区二区不卡片| 久久精品国亚洲a∨麻豆| 欧美成ee人免费视频| 亚洲日韩精品无码专区网站| 99这里视频只精品2019| 在线观看无码av网站永久| 国产成人精品午夜二三区波多野| 果冻传媒剧国产剧情mv在线| 97se亚洲国产综合自在线| 亚洲综合欧美在线一区在线播放| 狠狠做久久深爱婷婷| 免费看无码午夜福利片| 亚洲中文字幕无码天然素人 | 99精品电影一区二区免费看| 国产熟睡乱子伦视频| 亚洲精品人成网线在播放va| 4hu四虎永久在线影院| 久久综合综合久久av在钱| 免费国产乱理伦片在线观看| 亚洲欧美综合精品二区| 中文字幕日本特黄aa毛片| 亚洲精品无码成人a片蜜臀| 色五月丁香五月综合五月| 日本无码一区二区三区不卡免费| 欧美成人性视频在线播放| av无码一区二区二三区1区6区| 国产清纯在线一区二区vr| 亚洲一区二区无码影院| 成人乱码一区二区三区四区| 伊人精品成人久久综合97 | 美乳丰满人妻无码视频| 日本高清视频网站www| 77777五月色婷婷丁香视频| 国产免费又色又爽又黄软件 | 国产精品www夜色视频| 2020精品国产自在现线看|